<?xml version="1.0" encoding="utf-8" standalone="no"?>
<!DOCTYPE document PUBLIC "-//CNX//DTD CNXML 0.5 plus MathML//EN" "http://cnx.rice.edu/cnxml/0.5/DTD/cnxml_mathml.dtd">
<document xmlns="http://cnx.rice.edu/cnxml" xmlns:md="http://cnx.rice.edu/mdml/0.4" xmlns:m="http://www.w3.org/1998/Math/MathML" xmlns:bib="http://bibtexml.sf.net/" id="None">
  <name>Overview and Configuration of DAQ Devices</name>
  <metadata>
  <md:version>1.1</md:version>
  <md:created>2004/06/17 14:15:37 GMT-5</md:created>
  <md:revised>2004/07/16 15:29:03.264 GMT-5</md:revised>
  <md:authorlist>
      <md:author id="NationalInstruments">
      <md:firstname>National</md:firstname>
      
      <md:surname>Instruments</md:surname>
      <md:email>certification@ni.com</md:email>
    </md:author>
  </md:authorlist>

  <md:maintainerlist>
    <md:maintainer id="lizzardg">
      <md:firstname>Elizabeth</md:firstname>
      
      <md:surname>Gregory</md:surname>
      <md:email>lizzardg@rice.edu</md:email>
    </md:maintainer>
    <md:maintainer id="mshiralkar05">
      <md:firstname>Malan</md:firstname>
      
      <md:surname>Shiralkar</md:surname>
      <md:email>mshiralkar05@hotmail.com</md:email>
    </md:maintainer>
    <md:maintainer id="harika">
      <md:firstname>Harika</md:firstname>
      
      <md:surname>Basana</md:surname>
      <md:email>ilsai@rice.edu</md:email>
    </md:maintainer>
    <md:maintainer id="NationalInstruments">
      <md:firstname>National</md:firstname>
      
      <md:surname>Instruments</md:surname>
      <md:email>certification@ni.com</md:email>
    </md:maintainer>
  </md:maintainerlist>
  
  <md:keywordlist>
    <md:keyword>National Instruments</md:keyword>
    <md:keyword>Labview</md:keyword>
    <md:keyword>DAQ</md:keyword>
  </md:keywordlist>

  <md:abstract>In this lesson, you will learn about plug-in DAQ devices.</md:abstract>
</metadata>

  <content>
    <para id="p1">
      LabVIEW includes a set of VIs that let you configure, acquire
      data from, and send data to DAQ devices. Often, one device can
      perform a variety of functions--analog-to-digital (A/D)
      conversion, digital-to-analog (D/A) conversion, digital I/O, and
      counter/timer operations. Each device supports different DAQ and
      signal generation speeds. Also, each DAQ device is designed for
      specific hardware platforms and operating systems. Refer to
      <link src="http://ni.com/daq">ni.com/daq</link> for more
      information about DAQ devices.
    </para>
    <section id="s1">
      <name>DAQ System Components</name>
      <para id="s1p1">
	Before a computer-based measurement system can measure a
	physical signal, such as temperature, a sensor or transducer
	must convert the physical signal into an electrical one, such
	as voltage or current. You might consider the plug-in DAQ
	device to be the entire measurement system, but it is actually
	only one system component. You cannot always directly connect
	signals to a plug-in DAQ device. In these cases, you must use
	signal conditioning accessories to condition the signals
	before the plug-in DAQ device converts them to digital
	information. The software controls the DAQ system by acquiring
	the raw data, analyzing, and presenting the results.
      </para>
      <para id="s1p2">
	Consider the following options for a DAQ system:
	<list id="s1p2l1">
	  <item>
	    The plug-in DAQ device resides in the computer. You can
	    plug the device into the PCI slot of a desktop computer or
	    the PCMCIA slot of a laptop computer for a portable DAQ
	    measurement system.
	  </item>
	  <item>
	    The DAQ device is external and connects to the computer
	    through an existing port, such as the serial port or
	    Ethernet port, which means you can quickly and easily
	    place measurement nodes near sensors.
	  </item>
	</list>
      </para>
      <para id="s1p3">
	The computer receives raw data through the DAQ device. The
	application you write presents and manipulates the raw data in
	a form you can understand. The software also controls the DAQ
	system by commanding the DAQ device when and from which
	channels to acquire data. Typically, DAQ software includes
	drivers and application software. Drivers are unique to the
	device or type of device and include the set of commands the
	device accepts. Application software, such as LabVIEW, sends
	the drivers commands, such as acquire and return a
	thermocouple reading. The application software also displays
	and analyzes the acquired data. NI measurement devices include
	NI-DAQ driver software, a collection of VIs you use to
	configure, acquire data from, and send data to the measurement
	devices.
      </para>
      <section id="s1s1">
	<name>NI-DAQ</name>
	<para id="s1s1p1">
	  NI-DAQ 7.0 contains two NI-DAQ drivers--Traditional
	  NI-DAQ and NI-DAQmx--each with its own application
	  programming interface (API), hardware configuration, and
	  software configuration.
	  <list id="s1s1p1l1">
	    <item>
	      Traditional NI-DAQ is an upgrade to NI-DAQ 6.9.x, the
	      earlier version of NI-DAQ. Traditional NI-DAQ has the
	      same VIs and functions and works the same way as NI-DAQ
	      6.9.x. You can use Traditional NI-DAQ on the same
	      computer as NI-DAQmx, which you cannot do with NI-DAQ
	      6.9.x.
	    </item>
	    <item>
	      NI-DAQmx is the latest NI-DAQ driver with new VIs,
	      functions, and development tools for controlling
	      measurement devices. The advantages of NI-DAQmx over
	      previous versions of NI-DAQ include the DAQ Assistant
	      for configuring channels and measurement tasks for a
	      device; increased performance, including faster
	      single-point analog I/O and multithreading; and a
	      simpler API for creating DAQ applications using fewer
	      functions and VIs than earlier versions of NI-DAQ.
	    </item>
	  </list>
	</para>
	<para id="s1s1p2">
	  Traditional NI-DAQ and NI-DAQmx support different sets of
	  devices. Refer to the <link src="http://ni.com/daq">National
	  Instruments Web site</link> for the list of supported
	  devices. This lesson describes the NI-DAQmx API.
	</para>
	<para id="s1s1p3">
	  <cnxn target="s1s1f1"/> shows the measurement software
	  framework.
	</para>
	<figure id="s1s1f1">
	  <media type="image/png" src="NIDAQmxArch.png"/>
	</figure>
	<para id="s1s1p4">
	  When programming an NI measurement device, you can use NI
	  application software such as LabVIEW,
	  LabWindows™/CVI™, and Measurement Studio, or
	  open ADEs that support calling dynamic link libraries (DLLs)
	  through ANSI C interfaces. Using NI application software
	  greatly reduces development time for data acquisition and
	  control applications regardless of which programming
	  environment you use:
	  <list id="s1s1p4l1">
	    <item>
	      LabVIEW supports data acquisition with the LabVIEW DAQ
	      VIs, a series of VIs for programming with NI measurement
	      devices.
	    </item>
	    <item>
	      For C developers, LabWindows/CVI is a fully integrated
	      ANSI C environment that provides the LabWindows/CVI Data
	      Acquisition library for programming NI measurement
	      devices.
	    </item>
	    <item>
	      Measurement Studio development tools are for designing
	      your test and measurement software in Microsoft Visual
	      Studio .NET. Measurement Studio includes tools for
	      Visual C#, Visual Basic .NET, and Visual C++ .NET.
	    </item>
	  </list>
	</para>
      </section>
    </section>
    <section id="s2">
      <name>DAQ Hardware Configuration</name>
      <para id="s2p1">
	You must complete several steps before you can use the Data
	Acquisition VIs. The devices are configured for the computers
	in this class.
      </para>
      <section id="s2s1">
	<name>Windows</name>
	<para id="s2s1p1">
	  The Windows Configuration Manager keeps track of all the
	  hardware installed in the computer, including National
	  Instruments DAQ devices. If you have a Plug &amp; Play (PnP)
	  device, such as an E Series MIO device, the Windows
	  Configuration Manager automatically detects and configures
	  the device. If you have a non-PnP device, or legacy device,
	  you must configure the device manually using the <code>Add New
	  Hardware</code> option in the Control Panel.
	</para>
	<para id="s2s1p2">
	  You can verify the Windows Configuration by accessing the
	  Device Manager. You can see <code>Data Acquisition
	  Devices</code>, which lists all DAQ devices installed in the
	  computer. Double-click a DAQ device to display a dialog box
	  with tabbed pages. The <code>General</code> tab displays
	  overall information regarding the device. The
	  <code>Resources</code> tab specifies the system resources to
	  the device such as interrupt levels, DMA, and base address
	  for software-configurable devices. The <code>NI-DAQ
	  Information</code> tab specifies the bus type of the DAQ
	  device. The <code>Driver</code> tab specifies the driver
	  version and location for the DAQ device.
	</para>
	<para id="s2s1p3">
	  LabVIEW installs Measurement &amp; Automation Explorer (MAX),
	  which establishes all device and channel configuration
	  parameters. After installing a DAQ device in the computer,
	  you must run this configuration utility. MAX reads the
	  information the Device Manager records in the Windows
	  Registry and assigns a logical device number to each DAQ
	  device. Use the device number to refer to the device in
	  LabVIEW. Access MAX either by double-clicking the icon on
	  the desktop or selecting <code>Tools&gt;&gt;Measurement &amp;
	  Automation Explorer</code> in LabVIEW. The window in <cnxn target="s2s1f1"/> is the primary MAX window. MAX is also the
	  means for SCXI and SCC configuration.
	</para>
	<figure id="s2s1f1">
	  <media type="image/png" src="max.png"/>
	</figure>
	<para id="s2s1p4">
	  MAX detects all the National Instruments hardware including
	  the GPIB interface. Refer to <cnxn document="m12283">Instrument
	  Control</cnxn>, for more information about GPIB.
	</para>
	<para id="s2s1p5">
	  The device parameters that you can set using the
	  configuration utility depend on the device. MAX saves the
	  logical device number and the configuration parameters in
	  the Windows Registry.
	</para>
	<para id="s2s1p6">
	  The plug and play capability of Windows automatically
	  detects and configures switchless DAQ devices, such as the
	  PCI-6024E. When you install a device in the computer, the
	  device is automatically detected.
	</para>
      </section>
    </section>
    <section id="s3">
      <name>Channel and Task Configuration</name>
      <para id="s3p1">
	In Traditional NI-DAQ you can configure a set of <term src="#virtualchannels">virtual channels</term>, or a collection
	of property settings that include a physical channel, the type
	of measurement or generation specified in the channel name,
	and scaling information. In Traditional NI-DAQ and earlier
	versions, virtual channels are a simple method to remember
	which channels are used for different measurements. NI-DAQmx
	<term>channels</term> are similar to the virtual channels of
	Traditional NI-DAQ.
      </para>
      <para id="s3p2">
	NI-DAQmx also includes <term>tasks</term> that are integral to
	the API. A <term src="#task">task</term> is a collection of
	one or more channels and the timing, triggering, and other
	properties that apply to the task itself. A task represents a
	measurement or generation you want to perform.
      </para>
      <para id="s3p3">
	Channels created only inside a task are local. Channels
	defined outside a task are global and can be used
	separately. Configuring virtual channels is optional in
	Traditional NI-DAQ and earlier versions but is integral to
	every measurement you take in NI-DAQmx. In Traditional NI-DAQ,
	you configure virtual channels in MAX. In NI-DAQmx, you can
	configure virtual channels either in MAX or in a program, and
	you can configure channels as part of a task or separately.
      </para>
    </section>
  </content>
  <glossary>
    <definition id="virtualchannels">
      <term>virtual channels</term>
      <meaning>
	A collection of property settings that include a physical
	channel, the type of measurement or generation specified in
	the channel name, and scaling information
      </meaning>
    </definition>
    <definition id="task">
      <term>task</term>
      <meaning>
	A collection of one or more channels and the timing,
	triggering, and other properties that apply to the task
	itself. A task represents a measurement or generation you want
	to perform.
      </meaning>
    </definition>
  </glossary>
  
</document>