Complete the following steps to build a VI that acquires
temperature once every 0.5 seconds for 10 seconds, displays a
subVI front panel that shows the acquired data in a graph, and
keeps the front panel open until you click a button.
Open a blank VI and build the following front panel.
Use the following guidelines to assist you in building the
front panel.
-
The indicator to the right of the thermometer is a
digital display belonging to the
thermometer. Right-click the thermometer and select
Visible Items>>Digital Display from the
shortcut menu to display the digital value.
-
Change
# of data values to signed
32-bit integer (I32) representation.
-
Build the following block diagram.
-
Place
the Thermometer VI from a previous exercise on the block
diagram. This VI acquires the current temperature
value.
-
Place the
Wait Until Next ms Multiple function,
located on the Functions>>All Functions>>Time
& Dialog palette, on the block
diagram. Right-click the input, select
Create>>Constant, and type
500 in the constant to cause the
For Loop to execute every 500 ms.
-
Place the Multiply function, located on the
Functions>>Arithmetic &
Comparison>>Express Numeric palette, on
the block diagram. This function multiplies each
element of the output array by 0.50 to scale the
xx values to represent
the time interval at which the VI takes the
measurements.
-
Place the Pop-up Graph VI, located in the
C:\Exercises\LabVIEW Basics I
directory, on the block diagram. This VI plots the
temperature data on an XY graph.
-
Complete the block diagram as shown in the previous
figure.
-
Save the VI as
Use Pop-up Graph.vi in the
C:\Exercises\LabVIEW Basics I directory.
-
Configure the subVI to display its front panel when
called.
-
Double-click the
Pop-up Graph subVI to open its
front panel.
-
Select
File>>VI Properties.
-
Select
Window Appearance from the
Category pull-down menu.
-
Click the
Customize button. Configure
the window appearance as shown in the dialog box.
-
Click the
OK button twice and save and
close the subVI. If the front panel is not closed,
it will not close after the subVI runs.
-
Run the
Use Pop-up Graph VI. After the VI
acquires 10 seconds of temperature data, the front panel
of the Pop-up Graph VI displays and plots
the temperature data. Click the DONE button
to return to the calling VI.
-
Change the window appearance settings for the
Pop-up Graph subVI to the
Dialog window style.
-
Save and close the subVI.
-
Run the
Use Pop-up Graph VI again. The
Pop-up Graph subVI front panel window
behaves as a dialog box. For example, the window stays
on top of all other windows and uses the system colors.
-
Close all open VIs.
"A full introductory course on programming with LabVIEW."