Connexions

You are here: Home » Content » Hardware
Content Actions
Lenses

What is a lens?

Lenses

A lens is a custom view of Connexions content. You can think of it as a fancy kind of list that will let you see Connexions through the eyes of organizations and people you trust.

What is in a lens?

Lens makers point to Connexions materials (modules and collections), creating a guide that includes their own comments and descriptive tags about the content.

Who can create a lens?

Any individual Connexions member, a community, or a respected organization.

This content is ...
Affiliated with (?)
This content is either by members of the organizations listed or about topics related to the organizations listed. Click each link to see a list of all content affiliated with the organization.
  • This module is included inLens: Rice University ELEC 301 Project Lens
    By: Rice University ELEC 301As a part of collection:"ELEC 301 Projects Fall 2004"

    Click the "Rice University ELEC 301 Projects" link to see all content affiliated with them.

    Rice University ELEC 301 Projects
  • This module is included inLens: Rice University OpenCourseWare
    By: OpenCourseWare ConsortiumAs a part of collections:"Array Signal Processing", "ELEC 301 Projects Fall 2004"

    Click the "Rice University OCW" link to see all content affiliated with them.

    Rice University OCW
Tags

(?)

These tags come from the endorsement, affiliation, and other lenses that include this content.

Hardware

Our array was built using six Sony F-V100 omnidirectional microphones, spaced at 9.9 cm apart. We built a frame out of precisely cut 1" I.D. PVC pipe in order to keep the microphones spaced accurately apart and minimize phase error in our measurements. These microphones produced an average 1 mV p-p signal from the sinusoids that were used for the test program. The signals were fed into a six-channel amplifier to increase the voltage to .5 V p-p in order to achieve a usable range of the DAQ card. The amplifier was built using common 741 op-amps and care was taken to insure all the path lengths were approximately the same length. Following the amplifier, the signals were fed into a National Instruments 6024e DAQ card. The DAQ card was set to sample at 4000 Hz for a length of 2 seconds.

Test Setup

Once the signals were digitized, we were able to use the Labview code that we had developed using the simulated test signals and apply the same algorithm to the real life signals that we were recording. To generate test signals we used a second laptop to generate different frequency sinusoids on the left and right channel of the sound output and then used a set of speakers with extended cables to place them at different locations around the array. For the actual location of the tests, we set up the array in the middle of an open outdoor area in order to avoid sounds echoing off the walls of an enclosed space and causing unwanted interference.

Comments, questions, feedback, criticisms?

Send feedback